12/23/2023 0 Comments Adjustable plaster ring![]() The apparatus of claim 1, wherein the first cover is flexible and the second cover is hard.Ĩ. The apparatus of claim 1, where one of the first and second covers is flexible.ħ. The apparatus of claim 4, wherein the second cover includes a plate.Ħ. The apparatus of claim 1, wherein the second cover is attached to the plaster ring with one or more screws.ĥ. The apparatus of claim 2, wherein the wiring module conductors are configured with wire connectors.Ĥ. The apparatus of claim 1, wherein at least one of the wiring module conductors is electrically connected to the electrical box.ģ. An apparatus for use in an electrical distribution system, the apparatus comprising: an electrical box configured to accept at least one electrical power cable a plaster ring configured to be mounted to the electrical box, wherein the plaster ring has an open front face that provides access to an interior of the electrical box an electrical wiring module within the interior of the electrical box, the electrical wiring module including one or more conductors that couple the electrical wiring module to one or more of the power cables, the electrical wiring module further including one or more connectors to electrically couple to a functional module a first cover configured to protect one of more of the connectors on the wiring module and a second cover configured to substantially cover the open front face of the plaster ring.Ģ. Module systems and module manufacturing processesĬOMPLETION SYSTEM HAVING A SAND CONTROL ASSEMBLY, AN INDUCTIVE COUPLER, AND A SENSOR PROXIMATE TO THE SAND CONTROL ASSEMBLYġ. METHOD AND APPARATUS FOR USE IN PROVIDING WIRE STRAIN RELIEF WITH ENVIRONMENTALLY PROTECTED IRRIGATION DEVICES MOUNT STRUCTURE TO MOUNT POWER CONTROLLER ON VEHICLE BODYĮLECTRONIC COMPONENT EMBEDDED PRINTED CIRCUIT BOARD AND METHOD FOR MANUFACTURING THE SAMEĮLECTRICAL DEVICE, BAND STRUCTURE AND METHODS FOR SEALING AT LEAST ONE PORTION OF AN ELECTRICAL DEVICE OR A CIRCUIT BOARD HERMETICALLY SUBSTRATE FOR OXIDE SUPERCONDUCTOR AND PROCESS FOR PRODUCING SAME, AND OXIDE SUPERCONDUCTOR AND PROCESS FOR PRODUCING SAME Garvin didn't have them in 3/4" yet when I did the rough-in, but all the sizes are available now.LEAD WIRE ISOLATION STRUCTURE AND LIQUID CRYSTAL MODULE I also used Garvin 5/8 octagon rings for the lights in my 5/8" drywall ceiling, and they are all recessed 3/16" to 1/4". I'd save the adjustables for where you plan to install tile. The screws hold friction wedges to secure the extension versus a threaded adjuster like the Garvin ones. Steel City has some adjustable mud rings that go down to 1/2". I was able to tell this when I mounted them. The double-gang adjustables telescope all the way down and sit flat with the 1/2" drywall, but the single-gang ones stick out 1/8". I also have a couple Garvin adjustables in my kitchen to accommodate tile not yet installed. Note that switches near the horizontal drywall seam will appear proud when the drywall goes up, because of the tapered drywall edge, but will be flush once the joint is mudded.Įven if your mud rings end up 1/16" proud, which they won't, the cover plates will still sit flat. Not one stuck proud of the wall, and nearly all were a perfect fit. You lose 1/8" from the screws plus another 1/16" for the sheet metal thickness. They all ended up 3/16" to 1/4" recessed even with the boxes mounted properly-code-legal but just barely. Then, to be safe, I picked mud rings the same nominal size as the drywall. Of course, adjustable rings would be great, but nowhere local carries them unfortunately.Ĭlick to expand.I rewired most of my house with square boxes and mud rings and spent way too much time researching this same question. So seems less precise, but more easily fixable if using the same size. If the ring is sized to the drywall size and is recessed a bit it is easier to put a few of the shims in when installing the switches and outlets. ![]() On the other hand, if for some reason I get everything flush when installing, I could have a mudring that sticks out past the drywall slightly which can't be fixed. On one hand, I would love for it to be flush out of the gate, which is why people upsize. Meaning, for 1/2" drywall, using 5/8" vs. I have read that there is a very testy debate going on for years about sizing up vs. Old work plastic is actually fine with me, but for new work, metal is where I will be at. I swore off plastic after years of being frustrated at the terrible declining quality of them as years go by. I am going to be using mud rings in metal boxes for the first time as I am remodeling.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |